Dam Breach Modeling and the Assessment of the Self Rescue Zone

An interesting and informative paper by Mr. Bruno Neves of Brazil on HEC-RAS dam breach modeling and determining the self rescue zone, as well as the timing for alerting residents of the self-rescue zone.  The concept is tested using HEC-RAS with hypothetical 2D breach scenarios of the Santa Branca Dam in the Paraíba do Sul River in São Paolo State, Brazil.  Included within the paper is a comprehensive review of some of the most widely used parametric breach equations used today.





 Bruno NEVES


ABSTRACT

Saving lives during dam break events is the main topic of this article, considering that a precise definition of the self-rescue zone (area in which authorities supposedly are not able to provide support to the population at risk in case of dam break, within the first minutes of the event) is crucial for planning mobilization of population in case of flood inundation. This paper presents a comparison of hydrographs, highlighting their dispersion through the self-saving zone, and sheds some light on issues of the hydraulic model.   



1.    INTRODUCTION

Despite the low probability of a dam break situation, around 0.0001 per year, this sort of hazardous event may cause significant damage and considerable loss of life (Medeiros, 2008).

In Brazil, federal law 12.334/2010 has set the National Policy of Dam Safety which defines obligations to the stakeholders of dams. Through National Agencies of Natural Recourses, details of this regulation are being defined.

ANA (National Water National Agency) and ANEEL (Electric Energy National Agency) agree in their regulations on the definition of the Self Rescue Zone, as follows: The downstream region of a dam where authorities are not able to provide assistance prior to the arrival of the flood wave in case of dam break alert, which is assumed to be 10 kilometers or the distance the front end of the rupture wave can travel in 30 minutes.
Colorado Department of Natural Resources (2010) regulates that the simulation of dam break events shall take place to characterize and identify locations which may be potentially threatened.

The bibliography shows diversity in modeling methods of breach opening which may lead to equally diverse results regarding potential damage in the self-rescue zone.
This paper cites details that may be considered when modeling a dam break event and sheds some light on results acquired from different breach opening equations. The US Army Corps of Engineers software HEC-RAS 5.0 (Hydrologic Engineering Centers River Analysis System) was used and applied to Santa Branca Dam, an earthen dam located in São Paulo state in Brazil.

Monday, July 11, 2016

Weir Equations in HEC-RAS

Written by Christopher Goodell, P.E., D.WRE
Copyright © The RAS Solution 2016.  All rights reserved. 


HEC-RAS has the ability to simulate flow at hydraulic controls in a variety of ways.  
Bridges, culverts, inline structures, lateral structures, and SA/2D area connections can all act as hydraulic controls.  Effectively, they break up the conservation equations used between cross sections in a 1D reach and/or cells in a 2D area with empirically derived (and usually very stable!) equations.  Weir equations can be used to define flow over an obstruction and are available with all of the 5 hydraulic controls identified above.  However, there are a number of options to consider when selecting simulating weir flow in HEC-RAS.  HEC-RAS approaches weir flow with three different cases:  Ungated Inline Weirs, Ungated Lateral Weirs, and Gated Weirs.  They all begin with the same standard equation:

                                                                  (1)

Where:  Q = discharge, C =weir coefficient, L = weir crest length, H = Energy head over the weir crest.

But each of the three cases apply the weir equation slightly differently. 

Before I continue, I should discuss the difference between the weir coefficient and the discharge coefficient.  I see both of them used interchangeably, but they ARE different.  The weir coefficient (as shown above in the weir equation) is a lumped parameter that includes the discharge coefficient, the gravitational constant, and constants based on geometric properties. 
                                                                                   
                                                                                                                              (2)
Where Cd is the discharge coefficient.  

The discharge coefficient is dimensionless and therefore it is the same in both English (U.S. Customary) Units and SI Units.  The weir coefficient, since it is a function of the gravitational constant, is not dimensionless and therefore has different values depending on which unit system you are using.  For example, a weir coefficient (C) of 3.00 in English Units would be 1.66 in SI units.  But both share the same discharge coefficient (Cd) of 0.56.  For convenience, to convert an English weir coefficient to an equivalent SI weir coefficient, multiply the English weir coefficient by 0.552.  
Be very cautious when considering C versus Cd.  They are different but are often mistakenly used interchangeably.  In fact, you’ll see the coefficient Cd labeled occasionally in the HEC-RAS software and literature when discussing weir coefficient. 

Ungated Inline Weirs. 
When defining inline flow over an “ungated” obstruction (bridge, culvert embankment, inline structure, SA/2D area connection), you have two options for computing weir flow:  Broad Crested and Ogee.   
Figure 1.  Inline structure weir embankment editor.

Both use the same standard weir equation presented above in equation (1).

The only difference between the Broad Crested Option and the Ogee Option is that for the Broad Crested option, the user enters a weir coefficient for C.  For the Ogee option, the user enters a spillway approach height and the ogee’s design energy head, and HEC-RAS will compute the weir coefficient for you.  This may sound convenient, but as the name implies, this option should really be used only for ogee-shaped spillways.  And you would have to know what the design energy head is, a design parameter that is not usually easy to come by, unless you have the hydraulic design report for the spillway.  With both options, submergence reduction of the discharge is automatically calculated with their own respective methods (FHWA ,1978 for broad crested, and COE, 1965 for ogee).

Ungated Lateral Weirs.
Lateral weirs are entered in the lateral structure editor.  Inside the lateral structure’s weir embankment editor, you’ll see two options for weir computations:  Standard Weir Eqn. and Hager’s Eqn.

Figure 2.  Lateral Weir Embankment Editor.

In version 5.0.1, the Standard Weir Eqn. provides four options for the weir crest shape:  Broad Crested, Ogee, Sharp Crested, and Zero Height.  Caution!  Zero Height is NOT used when Standard Weir Eqn. is selected.  This is a bug and will most likely be fixed for future versions.  If you do select Zero Height and Standard Weir Eqn. together, HEC-RAS will just use the weir coefficient you provide with the broad crested methodology.  Sharp Crested is not fully functional in Lateral Structures for version 5.0.1.  You’ll notice that no additional input options (like Rehbock and Kindsvater-Carter, as discussed under the next section, “Gated Weirs) are available when you select Sharp Crested in the lateral weir embankment editor.  My guess is that if you select Sharp Crested, it too will default to the broad crested methodology. 

Broad Crested and Ogee work the same as with the ungated inline structures.

With Hager’s Equation, all four weir crest shapes are available, including the zero-height weir.  The same weir equation is used, but an adjusted weir coefficient is computed based on physical and hydraulic properties.  Each of the four weir types has its own method for computing the adjusted weir coefficient.  There is an input box for “default weir coefficient”.  This is only used for the first iteration of solving Hager’s Equation.  Since Hager is a function of hydraulic properties, it must be solved in an iterative fashion.  After the first iteration, the adjusted weir coefficient will be computed and used.  Page 8-18 of the Hydraulic reference manual discusses Hager’s equation and how the adjusted weir coefficient is computed. 

Zero-height weirs are used for cases where flow will leave a channel laterally, but there is no defined obstruction or hydraulic control separating the two.  Commonly this is used to simulate flow from a main channel up a tributary that is being modeled using a lateral structure and a storage or 2D area.  The HEC-RAS 2D manual has a table of lateral weir coefficients (Table 1). 

Table 1.  Lateral Weir Coefficients (from the HEC-RAS 2D Manual, page 3-50).

Notice the last category is “non elevated” overbank terrain.  If you wish to use the weir coefficients in this table to simulate a non-elevated weir, do not use the Zero-Height weir.  That is strictly for Hager’s equation and Hager’s method automatically computes the weir coefficient.  Instead, use the broad crested standard equation and enter in the non-elevated weir coefficient there. 

Gated Weirs. 

When modeling gated spillways at inline structures or lateral structures, users can provide a weir coefficient for flow over the spillway when the gate is completely opened, and out of contact with the flow (Figure 3). This is different from the discharge coefficient used for flow over the top of the inline structure (Figure 1). 

Figure 3. Inline Gate Editor

With gated spillways, the user has three options for the weir shape:  Broad Crested, Sharp Crested, and Ogee (Figure 4).  Broad Crested and Ogee work the same as previously discussed.  The Sharp Crested option also uses the standard weir equation but gives you three options for determining the discharge coefficient:  user-entered, compute with the Rehbock equation, or compute with the Kindsvater-Carter equation.  For both the Rehbock and Kinsvater-Carter methods, the weir coefficient will be computed independently at each time step. So you can have a varying discharge coefficient for varying heads. 

Figure 4.  Inline Gate Editor.

The Rehbock equation for the discharge coefficient was developed for rectangular weirs and is as follows:
                                                                                                                 (3)
Where P = Spillway approach height.  This value must be entered to use the Rehbock equation.  HEC-RAS will then compute the weir coefficient, C using equation (2).   According to Ippen (1950), this equation holds up well for values of H/P up to 5.  And it performs with fair approximation for H/P values up to 10. 

The Kindsvater-Carter method was developed in English units only and is as follows:

                                                                                                        (4)

Where Ce = effective weir coefficient, ft1/2/s
                kb = a correction factor to obtain effective weir crest length, ft
            kh = a correction factor with a constant value of 0.003 ft

The effective weir coefficient, Ce is a function of two ratios:  L/B and H/P, 

Where  L = Weir crest length
            B = Average width of the approach channel
            H = Energy head over the weir crest
            P = Spillway approach height

Ce is a function of both the relative width and relative depth of the approach channel and is taken from the following chart (note that the chart uses the variable h1 for H.  They are the same):

Figure 5.  Effective Weir Coefficient

kb is used to determine the effective length of the weir crest and is a function of the relative width of the approach channel.  It is taken from the following chart:

Figure 6.  Correction factor kb.

To use the Kindsvater-Carter method in HEC-RAS for a gated spillway, first select the weir shape as “Sharp Crested”.  Then select “Compute with Kinsvater-Carter eqn as the Weir Method.  You must then choose a relative approach channel width (L/b) and enter the spillway approach height, P (note, b is used in the HEC-RAS Inline Gate Editor for B.  They are the same). 

Figure 7.  Kindsvater-Carter Weir Method.

Remember, the Kindsvater-Carter equation was developed and is presented here in English units.  When using SI units, HEC-RAS will automatically convert the units appropriately.  So you can still enter a spillway approach height in meters if you are using SI units. 

The Kindsvater-Carter weir equation is built for rectangular weirs and “is particularly useful for installations where full crest contractions or full end contractions are difficult to achieve.”  (USBR 2001)  More information on the Kindsvater-Carter equation, including its limitations, can be found here:  http://www.usbr.gov/tsc/techreferences/mands/wmm/chap07_06.html

References:
Federal Highway Administration (FHWA), 1978.  Hydraulics of Bridge Waterways, Hydraulic Design Series No. 1, by Joseph N. Bradley, U.S. Department of Transportation, Second Edition, revised March 1978, Washington D.C.

Ippen, A.T. ,1950.  Channel Transitions and Controls, Chap. VIII in Hunter Rouse (editor): Engineering Hydraulics,” John Wiley & Sons, Inc., New York.  pp.496-588.

Unites State Bureau of Reclamation (USBR), 2001.  Water Measurement Manual, http://www.usbr.gov/tsc/techreferences/mands/wmm/

U.S. Army Corps of Engineers (COE), 1965.  Hydraulic Design of Spillways, EM 1110-2-1603, Plate 33.




Thursday, June 23, 2016

Tips and Tricks for Modeling Irrigation Canals and Structures in HEC-RAS

Written by Brian Wahlin, Ph.D., P.E., D.WRE | WEST Consultants
Copyright © The RAS Solution 2016.  All rights reserved.

In an earlier blog post, we discussed some details regarding modeling overflow gates in HEC-RAS.

These gates are typically used in irrigation canals. This blog post generated many interesting questions and comments regarding modeling irrigation canals in general using HEC-RAS. Thus, we felt it might be interesting to address some of these questions in a blog post devoted solely to modeling irrigation canals and structures using HEC-RAS.


One of the questions from the overflow gates blog post was:

“I have a question about external data interface for canal automation (EDI). I wanted to know if the project was success full [sic] and could simulate the real canal system.
I have seen in some articles that using Saint Venant equations is too complicated for canal automation purposes and needs lots of data. Instead they suggest to use industrial control system approach. Furthermore, in a book which has been published by ASCE http://www.asce.org/templates/publications-book-detail.aspx?id=6965, they suggest that to use similar approaches. I want to know your opinion.”

This question covers many topics from modeling irrigation canals using HEC-RAS to designing automatic controllers for irrigation canals.  It also references a project we completed several years ago where we linked an unsteady HEC-RAS model of the Central Arizona Project (CAP) Canal to a Supervisory Control and Data Acquisition (SCADA) program so that the operators of the CAP Canal could be trained using a hydraulic model rather than by operating the real canal.  CAP has an extensive SCADA system that allows them to monitor and control the entire 336-mile canal from their central control room.  

This is similar to the concept of how pilots are trained using a flight simulator instead of flying a real plane.  In a way, we created a “flight simulator” for canal operators.  To make this project successful, we had utilized many of the HECRASController routines and had to create a program that linked HEC-RAS to the SCADA system.  We called this program the External Data Interface (EDI).  We are also pleased that the question references the newly published ASCE Manual of Practice (MOP)131 Canal Automation for Irrigation Systems. This new publication is intended to be an update on recent advances in canal automation.  On a side note, I was one of the editors for MOP 131, so thanks for the plug on the book!

In reading this question, we first need to clarify something. As the reader points out, it is true that using the St. Venant equations to design a controller is not a good idea because of the non-linearity of those equations. Thus, controllers are typically designed using some sort of linearized approximations of the system (i.e., industrial control system approach).

However, when testing the performance of a designed controller, it is no problem to test them via simulations using the full St. Venant equations using unsteady HEC-RAS. In fact, you want to do this to make sure that the designed controller (designed using simplified linear approximations) will behave as expected in the real nonlinear world.

The EDI program that the reader refers to did work successfully. We were able to model the unsteady hydraulics of the CAP Canal successfully and had calibration data to verify the model performance. In this particular project, we did not actually design feedback controllers or test the controllers via hydraulic simulation as that was not the goal of the project. Instead, we used the EDI as an interface between the HEC-RAS model of the canal and the SCADA system used to manually monitor and control the canal (manual-centralized control). As mentioned earlier, the EDI program was crucial in making the canal operator “flight simulator” work. A schematic diagram of how the “flight simulator” for irrigation canals is set up and how the EDI program fits into this scheme is shown below. Note that the SimSuite program in the figure is a program that emulated field hardware and maintained physical information such as gate positions, water levels, and turnout flows.  SimProctor is a program used to assist in the training of the canal operators.



After posting the above response, the reader came back with a series of questions.  So, let’s go through these follow-up questions:

1.   “I was wondering if there is any publication available for the methodology which has been implemented in this project.”

      Yes, the results of our “flight simulator” project for the CAP was published in the proceedings for a US Committee on Irrigation and Drainage conference a few years ago.  We will also be speaking about this topic again at the upcoming ISHS conference in Portland in June 2016.  A link to the ISHS conference paper is given here:  https://drive.google.com/file/d/0B0bpiyLiUeRXRzBoUW9IRlpLQ28/view?usp=sharing
    
      2.  “How did you calibrate the model?”

      CAP collects data for the canal on a regular basis.  These data include water depths, gate openings, and flow rate estimates.  We used this information to adjust gate discharge coefficients and Manning’s roughness coefficients to perform the calibration of our model of the canal.  If you are doing an unsteady calibration, you will want to have the initial conditions start off at a steady state condition.
   
      3.   “Did you calibrate the pools one by one or calibrated [sic] couple of pools together?”

      Adjusting the gate discharge coefficients and Manning’s roughness coefficients can affect the water levels upstream and downstream if the gates are submerged.  Thus, we adjusted the gates one at a time, but always checked to make sure that the entire system calibration looked good as we were moving from one gate to the other.

      4.  “How did you model turnouts in HEC-RAS? Did you have instability issues in the turnouts?”

      Yes, we modeled turn outs.  The turnouts on the CAP Canal are locally automated to deliver a constant flow rate to the turnout regardless of the water level or flow rate in the canal.  Thus, the turnouts were modeled as constant outflow hydrographs (unsteady).  If you are doing a steady model, the turnouts would be modeled as a flow change location.  If you want your turnout to have the flow vary as a function of head in the canal, then you can place a lateral structure where the turnout is located and then put a gate on that lateral structure.  RAS will then calculate the flow through the gate based on the head from the water surface in the main canal.  If you are not modeling the water after it leaves the turnout, just have RAS remove the water from the system.  If you are modeling the water after it leaves the turnout, you will have to create another reach in RAS to model the lateral canal that the water from the turnout flows into.  You should not see instability issues due to turnouts. The photo above shows a typical turnout structure on an irrigation canal.

      5.   “Can HEC-RAS model water levels with +/- 5 centimeter accuracy in irrigation canals?”

      That really depends on how accurate your data are.  If you have poor information about your canal (e.g., you don’t have as-built plans or there has been settlement in the lining or there is lots of seepage), then you may not be able to get 5 cm accuracy.  Probably the largest uncertainty in the canals will be the flow rates.  You most likely will not know the flows in the canal to with +/- 5% unless you have very accurate flow measurement devices installed.  One suggestion would be to run a sensitivity test on the canal by varying the flows to get an idea regarding how much the water surfaces will fluctuate due to the uncertainty in your flow rates.

      Typically in an irrigation system, the water level upstream of a check gate is the “most important” depth.  The predicted water level at this location heavily depends on the gate discharge coefficient and the Manning’s roughness coefficient.  So if you do not know the gate discharge coefficient (and don’t have any calibration data to determine what it should be), then the water levels upstream of the check can be off by quite a bit.  The plot below shows the calibration results for an irrigation canal, where the diamond shapes indicate observed water levels. You can see from this plot that our calibrated model agrees well with some of the observed data points.  For other data points, there is some difference between the computed results in HEC-RAS and the observed data. Most likely, the areas where our calibration did not agree well were a result of the uncertainty in the observed data or flow rates.



6.  “What parameters did you put from [sic] designed controller in HEC-RAS?”

      Feedback controller design for irrigation canals in a complex topic.  We like to design the controllers for an irrigation canal using a linear approximation of the real canal using something called the integrator-delay model.  Using this model, the only two parameters needed to design the controller would be the delay time and the backwater surface area behind the pool. Both of these parameters can easily be obtained using your HEC-RAS model. These parameters are needed for each pool in your system.  Of course, these parameters can change as the flow rate changes, so if you design your controller for one flow rate and operate it at a completely different flow rate, the controller performance will not be as expected.  For canal pools that are completely under backwater, controller design is more complicated because of resonance that results from reflection waves. Details on modeling canals for controller design can be found in the ASCE MOP 131.  To actually design the controller, you can use techniques like Linear Quadratic Regulator or Model Predictive Control.  All of these topics are described in the ASCE MOP 131.

      7.  “Is it possible to use such approach for earthen canals? Do I need to re-calibrate the model after couple of years due to sediment and weeds?”

      Yes, you can use HEC-RAS to model an earthen canal.  Sediment and weeds can influence the Manning’s roughness coefficients.  Thus, the canal may respond differently over time due to weed growth and sediment, so this is something that you should consider. The figure below shows weeds growing along the banks of an earthen irrigation canal as well as along the bottom of the canal. These weeds were seasonal and only appeared in the summer months.  Another issue would be canal seepage in earthen canals.  If you performed a seepage test on a canal pool, you could get an estimate of the rate of water loss from the pool.  You could then model this seepage from the canal using unsteady outflow hydrographs or possibly the groundwater interflow internal boundary condition.  Without performing a seepage test, you would really need very good (and detailed) calibration data to determine the seepage losses.


8.  “Do you have any instability issues due to sudden opening/closing of the gates?”

      You can have instabilities any time you make a sudden change in RAS while using unsteady flow.  However, we have typically been able to get around these problems by adjusting the time step, the cross-sectional spacing, and the HTABs.  The CAP Canal model we mentioned had an inverted siphon immediately downstream of the check gates.  When the gates were slammed shut, the siphon would dry up and crash the model.  In this unique situation, pilot channels helped eliminate the instability.

      9.  “Have you built any physical model in a lab for irrigation canals and made a HEC-RAS model of the same canal and then compared the results?” 

      No, we have not done that and do not know of any situations where this has been done.

      10.  “Is it possible to use HEC-RAS to model sediment transport in irrigation canals? Is this model reliable?”

      Yes, it is possible to use HEC-RAS for sediment transport in irrigation canals.  A sediment transport model for an irrigation canal would be just as reliable as any other sediment transport model, which means it really depends on how the model is set up, what data are available, etc.  Care needs to be taken to use the correct sediment transport function for the canal.  Alternatively, there is a model developed specifically for sediment transport in irrigation canals called SETRIC, which was developed by IHE in the Netherlands.  If you are concerned about modeling the sediment transport in an irrigation canal, SETRIC may be a good option for you.



Tuesday, June 21, 2016

Last Chance to Register for HEC-RAS 2D in London July 19-21.




Less than one month away so we're making the final call.  This is your last opportunity to register for this class.  This will be a fantastic opportunity to learn how to set up and run 2D and 1D/2D HEC-RAS models using the newly released HEC-RAS 5.0.  I will be hosting this course in London England on July 19-21, 2016.  Register now!  Space is limited!

Please go here to register for the class.
  

If you have any questions, or to express interest in the class, please email Chris Goodell at cgoodell@westconsultants.com





This course will take place in  London,  19-21 July, 2016 and will be taught by Mr. Chris Goodell of WEST Consultants and The RAS Solution.

The course will be held at the Imparando conference/training facilities at - 56 Commercial Road, Aldgate East - E11LP in downtown London. 



Please register for the class using the following form:  
https://drive.google.com/file/d/0B0bpiyLiUeRXSVgtM0RpaUJXWEU/view?usp=sharing.

Since the beta version of HEC-RAS 5.0 was released in 2014 Chris Goodell has given the HEC-RAS 2D Modeling class more than 15 times throughout the United States and around the world in places like Pretoria, Milan, and Melbourne. 

Thursday, May 26, 2016

HEC-RAS 2D en España - HEC-RAS 2D in Spain

Para los compañeros usuarios de HEC-RAS viviendo dentro o cerca de España, mi colega Marty Teal estará dictando dos cursos de modelación bidimensional con HEC-RAS5.0 allá en Octubre: en Barcelona el 19-21 y en Sevilla el 24-26.

Me gustaría estar allá pero Marty habla español mucho mejor que yo :-)
Vaya aquí para más información.

For my fellow HEC-RAS Users who are in or around Spain, my colleague Marty Teal will be teaching our HEC-RAS 5.0 2D Course in two locations in October 2016.  Oct 19-21 in Barcelona and Oct 24-26 in Seville.

Wish I could be there, but Marty speaks much better Spanish then I do. :-)
For more information, click here.




And for you English-speaking HEC-RAS users, there is still space for more attendees at the London class in July.  But don't wait too long to register, there will be a limit.

Tuesday, May 17, 2016

Bridges in 2D Areas-Important Update!

Written by Christopher Goodell, P.E., D.WRE  |  WEST Consultants 
Copyright © The RAS Solution 2016.  All rights reserved. 

***Update:  I received a few very important comments about this post that I want to share.  

First, and this is very important:  These methods are not meant to be used to do any kind of detailed bridge design or bridge scour analysis (contraction, abutment, or pier scour).  The methods I present in this post are strictly as a means to include a bridge in a 2D area to gage its effect on the overall resulting flood inundation.  Meeting FHWA standards for bridge modeling requires much more information than these options will provide you.  


Second, Mark Forest posted a couple of very good comments that I would like to share. Please read his comments at the end of this post.


There have been a lot of requests for examples of how to model bridges in 2D areas.  First, let me state up front that in the current version (5.0.1) there is no direct way to put a bridge in a 2D area, like you would in a 1D reach.  That means, that we currently don’t have a way to use low flow bridge modeling approaches like Energy, Momentum, Yarnell, and WSPRO.  Likewise, you can’t use the high flow approaches (Energy, Pressure/Weir).  Hopefully this will be added to a future version.  

That being said, I’ll present three options for simulating bridges in 2D areas.  

To demonstrate these options, I used a dam breach model adapted from HEC’s Bald Eagle Creek data set.  The animation is included at the end of this article. 

Friday, May 6, 2016

HEC-RAS 2D Modelling Training in London July 19-21, 2016




This will be a fantastic opportunity to learn how to set up and run 2D and 1D/2D HEC-RAS models using the newly released HEC-RAS 5.0.  I will be hosting this course in London England on July 19-21, 2016.  Register now!  Space is limited!

Please go here to register for the class.
  

If you have any questions, or to express interest in the class, please email Chris Goodell at cgoodell@westconsultants.com






This course will take place in  London,  19-21 July, 2016 and will be taught by Mr. Chris Goodell of WEST Consultants and The RAS Solution.


The course will be held at the Imparando conference/training facilities at - 56 Commercial Road, Aldgate East - E11LP in downtown London. 




Please register for the class using the following form:  
https://drive.google.com/file/d/0B0bpiyLiUeRXSVgtM0RpaUJXWEU/view?usp=sharing.

Since the beta version of HEC-RAS 5.0 was released in 2014 Chris Goodell has given the HEC-RAS 2D Modeling class more than 15 times throughout the United States and around the world in places like Pretoria, Milan, and Melbourne.